HVAC/ECU Systems

FSI North America’s HVAC and Filtration units utilize an Air Safety Process which captures, contains and neutralizes all air borne bio-aerosols while providing climate control. These units can supply heating, cooling, HEPA filtration, UVGI, positive pressure (collective protection), negative pressure (medical isolation), continuous monitoring of isolation area and in one unit. The F-EMAT3T meets and exceed CDC guidelines for infectious isolation requirements. HEPA filtration is an acceptable means to filter radioactive particulates from the air. Create POSITIVE PRESSURE inside shelters, buildings and most enclosures and create a FRESH air environment.

PORTABLE HVAC Systems

F‐DI25HP0105CM

FSI Portable HVAC - 2.5 Ton/30,000btu AC - 30,000btu Heat Pump/10kw resistance heat. 208/230V 30AMP SINGLE PHASE 60HZ. 29”Hx59”Lx33”W. 330LBS.

F-DI35HP0100CM

FSI Portable HVAC - 3.5 Ton/42,000btu AC - 40,000btu Heat Pump/10kw resistance heat. 208/230V 30AMP SINGLE PHASE 60HZ. 40”Hx56”Lx35”W. 425LBS.

F-DI40HP0100CM

FSI Portable HVAC - 4 Ton/48,000btu AC - 46,000btu Heat Pump/10kw resistance heat. 208/240V 35/41AMP SINGLE PHASE 60HZ. 42”Hx60”Lx34”W. 525LBS.

F-DI50HP0100CM

FSI Portable HVAC - 5 Ton/60,000btu AC - 60,000btu Heat Pump/15kw resistance heat. 208/240V 52/61AMP SINGLE PHASE 60HZ. 42”Hx60”Lx34”W. 550LBS.

F-DI100HP0100CM

FSI Portable HVAC - 10.0 Ton/123,000 btu AC. Unit w 30KW (102,300btu/h of heat. Each KW is 3410btu/h).

F-DI125HP0100CM

FSI Portable HVAC - 12.5 Ton/156,000 btu AC.

f-emat-5t

HVAC & Filtration Systems

F-EMAT3T

Portable quadruple combination AC/Air Heat/HEPA/UVGI air filtration system/Ozone post event decontamination of shelters – ideal for surge capacity systems. HEPA filtration 99.99 % @ 0.3 micron/99.97 % at 0.1 micron, 18″ X 24″ X 12″ – 1,100 CFM, 5,000 cubic ft. normal filter loading. AC = 36,000 BTU. Air heat = 68,000 BTU. Post event Ozone Decon. Manual positive or negative pressure control. Includes (3) 20′ power cables, 220V, (2) 14″ X 8′ Lengths of HD ducting. 15 air changes per hr., approx. 400 lbs., 45″ X 28″ X 48″.

F-EMAT5T

Portable quadruple combination AC/Air Heat/HEPA/UVGI air filtration system/Ozone post event decontamination of shelters – ideal for surge capacity systems. HEPA filtration 99.99 % @ 0.3 micron/99.97 % at 0.1 micron, 24″ X 24″ X 12″ – 2,400 CFM, 10,000 cubic ft. normal filter loading. Unit provides 60,000 btu cooling and 94,000 btu heat pump heat with 68,000 btu resistance heat. Post event Ozone Decon. Manual positive or negative pressure control. Includes (3) 20′ power cables, 220V, (2) 14″ X 8′ Lengths of HD ducting. 30 air changes per hr., approx. 500 lbs., 68″ X 36″ X 68″ The F-EMAT5T meets and exceeds CDC guidelines for infectious isolation requirements.

F-HC-7400

Portable Multi combination AC/Air heat/HEPA air filtration/UVGI decon system.  15,000 CFM 110V/30,000 CFM Air Cool, 9,180 CFM Air Heat, HEPA air filtration 99.99 % @ 0.3 micron, UVGI decon.  46″ H X 43″ W X 35″ D (116 X 109 X 89 cm), 235 lbs. (107 Kg).  With 10 ” (25 cm) air returns, dual HD Ducting, dual high capacity condensers w. fans. Est. capability of 300 sq. ft. or less approx. 110V is standard unless specified 220V at time of order. Eff. 07/12 Must purchase F-HCRH below with each HVAC unit to operate the thermostat inside the return air opening

Controllers, Hoses, & Parts

F-RPLC-CONT

Replacement thermostatic controller for an EMAT 3/5T

F-HCD

8″  x 15′ Replacement Insulated Ducting Supply Hose for F-HC-7000/7360/7400

F-HCRH

10′ x 15′ Insulated Return Hose for F-HC-7000/7360/7400. Must purchase F-HCRH with each F-HC-7000/7360/7400 to operate the thermostat inside the return air opening.

F-EMAT-5T-RF

Replacement HEPA filters for F-EMAT 3T and 5T Systems – spec. w order (sold each)

F-EMAT37-100APC

Additional 100ft auxiliary power cable for F-EMAT3T

F-EMAT3T-100PPC

Additional 100ft primary power cable for F-EMAT3T

F-EMAT5T-100PPC

Additional 100ft power cable for F-EMAT5T