Patient Isolation

FSI Patented containment chambers to safely transport victims of Biochem incidents while protecting care givers from exposure. All FSI Isolation Chambers are designed to adapt to all existing stretcher models.

Looking for our Pneumatic Isolation Shelters instead? Click here!

Isolation Chambers

F-INPIC-1

F-INPIC replacement ISO chamber only – no pumps, filters, caps, other – CHAMBER ONLY

F-INPIC-4

Isolation Chamber complete with PAPR w. D cell Alkaline Batteries for up to 6 hours of continuous use before battery change out required, creates -negative/positive flow when connected to supplied HEPA air filter system (6 NATO standard 40mm threaded HEPA filters supplied); 12 – 4″ W, re-sealable Red colored access ports to allow passage of O2/intravenous tubes from outside to patient; of HD vinyl materials, full head to foot HD Zipper; 7 flexible plastic arches for structural support; 2″ W belt system w. 4 hand grips on ea. side to lift patient in chamber and/or to fasten chamber to stretcher/bed; 12 air exc./hr.; approx 77″ L X 28″W X 19″ H, Wt. approx. 30 lbs.; store size in supplied carry bag approx. 20″ L X 27″ W X 8″ H

F-INPIC-5A

Isolation Chamber complete with PAPR w. D cell Alkaline Batteries for up to 6 hours of continuous use before battery change out required, creates -negative/positive flow when connected to supplied CBRN type air filter system (6 NATO standard 40mm threaded CBRN filters supplied) ; 12 – 4″ W, re-sealable Red colored access ports to allow passage of O2/intravenous tubes from outside to patient; of HD vinyl materials, full head to foot HD Zipper; 7 flexible plastic arches for structural support; 2″ W belt system w. 4 hand grips on ea. side to lift patient in chamber and/or to fasten chamber to stretcher/bed; 12 air exc./hr.; approx 77″ L X 28″W X 19″ H, Wt. approx. 30 lbs.; store size in supplied carry bag approx. 20″ L X 27″ W X 8″ H

F-INPIC-9BAR

Bariatric Iso chamber 77″ L X 36″ W X 30″ H approx. made to handle over sized 600 lb. + to come complete with extra strapping on sides and down middle to support weight, and much larger heavier duty PVC support spleens/arches to form a correct chamber over and around patient – complete with PAPR w. D cell Alkaline Batteries for up to 6 hours of continuous use before battery change our required, creates -negative/positive flow when connected to supplied HEPA air filter system (6 NATO standard 40mm treaded HEPA filters supplied); 12 – 4″ W, re-sealable Red colored access ports to allow passage of 02/intravenous tubes from outside to patient; of HD vinyl materials, full head to foot HD Zipper; 7 + flexible plastic arches for structural support; 2″ W belt system w. 8 approx. hand grips on ea. side to lift patient in chamber and/or to fasten chamber to stretcher/bed; Patient may only be lifted off bed or table onto a suitable backboard. 12 air exc./hr.; approx. Wt. approx. 70 lbs.; store unit in supplied carry bag approx. 30″ L X 37′ W X 19″ H

Optional Isolation Chamber Accessories

F-INPIC-C2A1X6

F-INPIC-C2A1X6

QTY. OF 6 Nato Style threaded HEPA filters 40 mm for F-INPIC units Priced per 6 pack *Qty 6 Required to operate F-INPIC. NO SHELF LIFE EXPIRY DATE ON HEPA FILTERS

F-INPIC-CBRN-3

F-INPIC-CBRN-3

3 PACKS (Qty: 3) CBRN rated filter 40 mm Nato threaded Style for F-INPIC units. Priced per 3 pack. *Qty 6 Required to operate F-INPIC. 5 YEAR SHELF LIFE ON CBRN FILTERS

F-INPIC-GP

F-INPIC-GP

Qty. of 1 (one) universal sized Butyl Rubber glove to attach to Isolation Chamber access port. Detailed specs below

F-INPIC-GP2

Per Pair of Universal (fits either hand) gloves of Butyl Rubber to attach to Isolation Chamber access port Price per PAIR. 14 Mil thickness solution dipped butyl. 14″ L, black color, curved hand; to MIL-DTL-43976, Type 11; physical properties to ASTMD412; rolled bead O ring design for positive seal

F-INPIC-PAPR

F-INPIC-PAPR

Replacement “D” Cell Battery PAPR.  *Can also replace old Rechargeable Battery Models

F-INPIC-RC

F-INPIC series Red color molded closure thread on Port/Cover, 4-pack

F-INPIC-MP

F-INPIC membrane port – molded casing 5.5″, natural rubber 1/16″, screwable to 4″ Flange

F-INPIC-O2C

O2 ports – quick disconnnect clip – priced each * 1 PER INPIC IS SUPPLIED AT NO ADDED CHARGE

Isolation Beds

F-AI-77      

F-AI-77

Portable Negative Pressure Medical Isolation System Bed System) offers negative pressure “medical isolation” that exceeds CDC guidelines to isolate individual infectious patients. These individual medical isolation units provide superior protection for anyone coming in contact with a suspected infectious individual. Applications include Emergency Rooms, Outpatient Clinics, Acute Care Inpatient areas, Portable Field Hospitals and Doctors’ Offices. The unit offers a complete air change in isolation area every 6 seconds; does not need external ventilation and protects healthcare staff from exposure to infectious disease. In addition the unit surpasses CDC guidelines for infectious isolation requirements and exceeds all existing and proposed OSHA standards. The unit is a FDA cleared Class II medical device. Specs: 55″L X 38″W X 76″H, 110 volts, air flow 450 low 700 high, 385lbs.

F-AI-77      

F-AI-77P

Portable Positive Pressure Medical Isolation System Bed System) offers positive pressure “medical isolation” that exceeds CDC guidelines to isolate individual infectious patients. These individual medical isolation units provide superior protection for anyone coming in contact with a suspected infectious individual. Applications include Emergency Rooms, Outpatient Clinics, Acute Care Inpatient areas, Portable Field Hospitals and Doctors’ Offices. The unit offers a complete air change in isolation area every 6 seconds; does not need external ventilation and protects healthcare staff from exposure to infectious disease. In addition the unit surpasses CDC guidelines for infectious isolation requirements and exceeds all existing and proposed OSHA standards. The unit is a FDA cleared Class II medical device. Specs: 55″L X 38″W X 76″H, 110 volts, air flow 450 low 700 high, 385lbs.

Isolation Cubes

F-DAT1R-66

5’ X 5’ X 8’H fully enclosed 360 degree patient visibility, inflatable room/cube/chamber for patient isolation within a facility.  The “CUBE” is designed to meet and exceed the CDC requirement of 12 ACH/HR air exchanges per hour and 0.01 inches of water column of negative pressure when used with appropriate FSI air filtration products.  For outside access to the patient inside the ISO-ROOM available an optional DATWGG may be purchased – consists of integrated gauntlets, and HD chemical resistant gloves for decon of patients/first responders from the outside of FSI DAT series decon showers by an attendant/doctor/nurse/other.  ISO ROOM may also be adapted for use as a positive air flow system.

F-DAT1R-99

9’ X 9’ X 8’H fully enclosed 360 degree patient visibility, inflatable room/cube/chamber for patient isolation within a facility.  The “CUBE” is designed to meet and exceed the CDC requirement of 12 ACH/HR air exchanges per hour and 0.01 inches of water column of negative pressure when used with appropriate FSI air filtration products.  For outside access to the patient inside the ISO-ROOM available an optional DATWGG may be purchased – consists of integrated gauntlets, and HD chemical resistant gloves for decon of patients/first responders from the outside of FSI DAT series decon showers by an attendant/doctor/nurse/other.  ISO ROOM may also be adapted for use as a positive air flow system.

F-DAT1R-912

9’ X 12 X 8’H fully enclosed 360 degree patient visibility, inflatable room/cube/chamber for patient isolation within a facility.  The “CUBE” is designed to meet and exceed the CDC requirement of 12 ACH/HR air exchanges per hour and 0.01 inches of water column of negative pressure when used with appropriate FSI air filtration products.  For outside access to the patient inside the ISO-ROOM available an optional DATWGG may be purchased – consists of integrated gauntlets, and HD chemical resistant gloves for decon of patients/first responders from the outside of FSI DAT series decon showers by an attendant/doctor/nurse/other.  ISO ROOM may also be adapted for use as a positive air flow system.

Related links

DAT6012-IS
To View FSI's Isolation Shelters, Click Here
Scroll to Top